TROUBLESHOOTING AND REPAIR

F-17

F-17

LN-25™

690

691

512

500

555

667

621

J1

J3

J4

J2

2. C h e ck fo r t h e p r e s e n c e o f t h e D C vo l t a g e

applied from plug J1 pin 1 (667+) to plug J1 pin

3 621(-). See Figure F.8.or F.8.a.

3. Check for the presence of 5 to 6 VDC from lead

6 9 0 ( + ) t o l e a d 6 9 1 ( - ) a t s o l e n o i d va l ve.

The LN-25™ trigger circuit must be activated

or the purge button must be pressed.

4. If the above voltage reading is not correct at the

solenoid valve, check for 5 to 6VDC at plug J2

pin 3 lead 690(+) & pin 6 lead 691 (-).

See

Figure F.8.

5. If the above voltage check is not correct, the

control board may be faulty. Refer to the wiring

diagrams in the Electrical Diagrams Section.

The appropriate jumper plugs may be used to

isolate and check suspect contactor or remote

control boards

NOTE: Machines with Codes above 10100 that

have been upgraged to the L12253-[ ]
Control boardhave thesme connection
points ad shown in Figure F.8 for the
supply and solenoid voltages

GAS SOLENOID VALVE AND CONTROL PC BOARD TEST

(FOR CODES ABOVE 10500 ONLY)

(continued)

FIGURE F.8. – CONTROL PC BOARD.

G3425