Issue 1

April 1997

35

Feature Descriptions

used. If zero is entered, then there is no coverage. If a valid coverage path
number is entered, then that coverage path is used.

The PMS can control the coverage path only if the PMS Protocol Mode is set to
“Transparent.” If the PMS is in the “Normal” mode, the server will default to a
“No PMS” mode.

When the PMS is fully active, the following features interact with the Call
Coverage feature:

Check-In — The coverage path for the room is set to the path given in the
“check-in” message. If the path in the “check-in” message is blank, then
the Default Coverage Path for Client Rooms is used.

Check-Out — The coverage path for the room is set to the default cover-
age path.

Room Change — The coverage path is moved from the old room to the
new room. The old room is given the default coverage path.

Room Swap — The coverage paths of the two rooms are swapped.

User Operation

0

There is no special user operation required for this feature.