44

Issue 1

April 1997

Controlled Restrictions

change system-parameters feature

On Page 3 of this form, add the intercept treatment desired for the Out-
ward/Toll, Termination (Do Not Disturb), and Station-to-Station restricted
calls in these fields:

Control Outward/Toll Restriction Intercept

Treatment

Controlled Termination Restriction (Do Not Dis-

turb)

Controlled Station to Station Restriction

Callers that encounter one of these restrictions can be routed to an
announcement, the attendant, Call Coverage (for Termination Restriction
only), an extension, or to intercept tone. If you select announcement or
extension, you must enter the appropriate extension number.

If restricted calls are routed to a recorded announcement, the specific
announcement must be recorded and assigned to the correct extension
number.

change system-parameters hospitality

On Page 1 of this form, enter an assignment in the

Controlled

Restrictions Configuration

field. If your server has no PMS or

the guest room telephone restrictions are not controlled by the PMS,
enter act-nopms in this field. If the guest room telephone restrictions are
controlled by the PMS, enter act-pms in this field. The PMS vendor
should be consulted concerning this setting.

change feature-access-codes

Enter feature access codes for the Group-Controlled Restrictions and the
User-Controlled Restrictions.

Required Hardware

0

There is no special hardware required for this feature.