Bilge pump inputs (2), Boat remote user’s manual 50 – Phonetics Boat Remote User Manual

Page 50

Advertising
background image

Boat Remote User’s Manual

50

Bilge Pump Inputs (2)

The Bilge Pump Inputs will monitor the number of on/off cycles and
the accumulated run time of your bilge pumps. The alarm param-
eters can be programmed to detect whether the bilge pump runs too
frequently (cycle rate alarm) or for too long a period (maximum run
time alarm). To aid in determining the appropriate alarm parameters
for your boat, set the input mode to status only and monitor the
display for a day or so. It will show bilge pump activity as follows:

Bilge Pump 1

OFF

Cycle: 0

Time:0:00

Max Cycle Rate:

0

Max Runtime:

0:00

1.

The real time status, on or off, of the bilge pump.

2.

Number of cycles and accumulated run time over a 24 hour
period starting at 12 am. (This resets to 0 at 12 am)

3.

Maximum # of cycles over the programmed cycle rate alarm
period.

4.

Maximum run time of any one cycle.

To program the bilge pump alarm parameters:

Press

SET

.

Press

BILGE

#1 or

BILGE

#2.

or

The input mode will be displayed. Press the

MODE

key on the keypad

until the appropriate mode is shown on the display. The default for
bilge #1 is active. The default for bilge #2 is off. Press

ENTER

.

Press the

MODE

key to toggle through the three input modes.

Press

ENTER

.

Advertising