Chapter 5: Troubleshooting

75

SYSTEM menu and adjust if necessary.

CAUSE: The Boat Remote is connected to an incompatible tele-
phone line.

SOLUTION: Some telephone systems will not allow the telephone to
ring beyond 4 rings. If your Boat Remote’s Rings Until Answer is set
at more than 4 rings you may not be able to access the unit. Try
setting the Rings Until Answer to less than 4 rings. If this does not
correct the problem, it may indicate telephone line incompatibility. In
this case, try connecting the Boat Remote to a standard residential
telephone line.

PROBLEM: The Boat Remote and another telephone answering
device (sharing the line) answer incoming calls simultaneously.

CAUSE: The Boat Remote’s number of Rings Until Answer is set to
the same number of rings for the other device.

SOLUTION: Change the number of Rings Until Answer for the Boat
Remote to a number greater than the rings for the other device.
Also, make sure the TAD (Telephone Answering Device) option is
set to ON in the SYSTEM menu.

PROBLEM: The Boat Remote recites the alarm message over
the telephone, but is silent at the installation site.

CAUSE: The speaker is turned off.

SOLUTION: Turn the speaker on by changing the speaker on/off
parameter in the SYSTEM menu.

TEMPERATURE MONITORING

PROBLEM: The temperature reading is -20.1

°

F or -29.1

°

C.

CAUSE: The temperature sensor has been disconnected or has a
broken wire.

SOLUTION: Examine the wires to the temperature sensor and
connect or replace the wiring.

PROBLEM: The temperature reading is 160.1

°

F or 72.1

°

C.

CAUSE: The temperature sensor wires are touching.

SOLUTION: Verify and correct wiring.

PROBLEM: The temperature reading is inaccurate.

CAUSE: An incompatible temperature sensor is attached to the Boat
Remote.

Advertising