Porsche 944 User Manual

Page 118

Advertising
background image

24

Air Flow Controlled Fuelinjection

944

Testing and adjusting specifications

Model 87 onward

Engine type M 44.40/41 (3.0 I)

Test

Specifikation

Remarks

Electric fuel

pump

Min. delivery

rate 850 cm

3

/30 s

Fuel pressure

(engine stationary)

DEE relay

jumpered

3.8 +- 0.2 bar

Checking value at

idle

approx. 3.3 +- 0.2

bar

Leak test

min. pressure after

20 Min.

2.0 bar

Idle speed

rpm

CO values %

ppm

without catalytic

converter

840 +- 40 **

0.5...1.5

<= 300

with

catalytic

converte

840 +- 40 **

0.4...1.2 *

<= 300 *

** Idle speed

can only now be

checked. Idle adjust-

ment no longer

applies.

* Measured upstream at

catalytic converter and

Lambda HC value

probe connector not

separated

CO adjustment no

longer applies.

Note

Carry out working procedure checking delivery rate of fuel pump and checking fuel

pressure as described an Pages 20 - 102 and 24 - 103 respectively.

Tightening torque for cap nut 12 Nm.

24 - 102

Testing and adjusting specifications

Printed in Germany - XIX, 1989

Advertising