Fuel System - Electronic Control

944 S/944 S2

Fault, Fault Code

Possible Causes, Elimination, Remarks

Tank venting valve is not activated permanently.

Test must be performed within 7 minutes after starting an engine having

operating temperature (interrupt tank venting valve activation approx. 75

seconds afterward and then continue).

Start engine and accelerate. This must be displayed in the tester for an engine

at operating temperature:

Signal will be wider as the air flow rate increases!

Check path according to the wiring diagram if there is no signal.

Replace control unit if necessary.

Test Point

17:

Check

Engine

warning

lamp

Fault Code

1_45

(California as

of

1991 models)

A ground signal from control unit plug terminal 22 goes to and switches on the

"Check Engine Lamp", if a component influencing emission control fails.

If the "Check Engine" warning lamp fails, this fault is stored in the fault

memory.

Check by supplying ground to control unit plug terminal 22 and turning on the

ignition.

Always replace a faulty display lamp with a specified lamp.

D 24/28 - 20

DME - Diagnosing/Troubleshooting

Printed In Germany - XXI, 1989