Self-diagnosis 944 – Porsche 944 User Manual

Page 48

Advertising
background image

03

Self-diagnosis

944

After pressing the key > , a selection menu is displayed:

Menu

1 = Fault memory

2 = Drive links

3 = Input signals

>

< Menu

1 = System adaptation

In the example - press key 1. There then follows the display of

the number of errors which are stored (if any).

Number of

faults

- 2 -

Proceed with key >

Additional info to

every display with

key 1

continue:

>

Proceed with key >

Error output:

1: Engine

temperature sensor 2

Short to ground

not present

If key 1 is pressed instead of the > key, the corresponding error

code display appears (the last two digits of the flashing code).

Fault code: - 14 -

Proceed with key >

Further errors are displayed (if they exist):

2 : Idle contact

Short to ground

present

If key 1 is pressed instead of key > the corresponding error-code

display appears (the last two digits of the flashing code).

Fault code: - 12 -

After the last displayed error, the following instruction appears:

Repair fault accord-

ing to repair

instructions

Continue:

>

Proceed with key >

Fault repaired ?

1 = yes

3 = no

Return to display "No. of errors" with key 3.

Proceed with key 1:

Fault memory

1 = Erase

3 = Do not erase

If key 3 is pressed:

= Return to menu "error memory".

The error memory is not erased!

Proceed with key 1:

Fault memory

has been cleared

Return:

N

The test scope "Read-out error memory" is terminated

at this point.

3.2 Actuator diagnosis

If an actuator is selecled, this is triggered by the ECU so that it can

be checked for correct functioning.

The various actuators components are gone through one after

the other and are selected with the > key.

Operate the Systemtester 9288 as described under 3.1 until

the following menu display appears:

Menu

1 = Fault memory

2 = Drive links

3 = Input signals

>

After pressing key 2, the display for the first actuator appears:

Injector

to activate

1 = Start

Continue:

>

If key > is pressed, the next actuator is selected.

Pressing key 1 results in the following instruction:

Can injectors be

heard / felt?

1 = yes

3 = no

03 - 36

Operating instructions for System Tester 9288

Printed in Germany - XXIV, 1991

Advertising