03

Maintenance, Self-diagnosis

944

Press the green key until the ctear symbol

ap-

pears on the function display. This activates

the first testing step and the injection valves

are activated.

Display:

The injection valves must all operate audibly

or tangibly.

Note:

If later attempts are made to start the engine,

starting difficulties may occur because a

slight

residual amount of fuet is injected during this

testing step.

The testing steps remain in operation until the

green key is again pressed on the tester and

the clear symbol appears.

The next testing step is initiated by again

pressing the green key.

Refer to the test code list for the sequence

of

testing steps.

03 - 8

Actuator and input signal function checking

Printed in Germany - XVI, 1987