24/28

Fuel System - Electronic Control

944 S/944 S2

Fault, Fault Code

Possible Causes, Elimination, Remarks

Turn off ignition and reconnect plug if the voltage values have been reached.

Remarks:

Control unit produces replacement values in case of air flow sensor failure

(emergency running program).

Injection signal from nominal air of the idle speed volumetric efficiency control

for idle or a constant injection signal for partial load and full load ranges.

Test Point 6:

Idle speed

control (V)

Fault Code

1_22 only S2

Element Activation Menu

If pulse cannot be heard, check:

Power supply

Connect a voltmeter on terminal 2 and

ground of the disconnected idle speed

control plug.

Turn on ignition.

Display: battery voltage

No display:

Check power supply according to the wiring diagram.

Control signal test

The pulse duty factor in % can be read direct in the "actual value" menu with a

9288 System Tester.

Function test: Switch on electric power consumers with engine running at idle

speed. The pulse duty factor must change and the idle speed must remain

constant.

If not:

D 24/28 - 14