Porsche 944 User Manual

Page 144

Advertising
background image

24/28

Fuel System - Electronic Control

944 S/944 S2

Fault, Fault Code

Possible Causes, Elimination, Remarks

Test Point 2:

Idle speed

contact ( )

Ground short

Fault Code 1_12

Check via circuit input test with 9288 System Tester or 9268 Tester.

Select test step and operate accelerator pedal.

9288 Display: Idle speed contact made

Idle speed contact broken

9268 Display: 1332 (idle speed contact made)

0000 (idle speed contact broken)

No Display:

Pull off plug on DME control unit.

Connect ohmmeter between terminal 52 and terminal 24 with help of test

leads.

Display:

Throttle valve closed

Throttle valve opened to gap of

< 10

> 1° =

If the value of the idle speed contact is not reached in this test, the test

should be repeated direct on the throttle valve switch as described below.

Pull off plug on throttle valve switch. Connect ohmmeter between terminals 1

and 2 of the throttle valve switch with help of test leads.

Display:

Throttle valve closed

Throttle valve opened to gap of

< 10
> 1° =

Idle speed

contact ( )

Break

Fault Code 1_15

Testing same as described for ground short

(fault stored in memory as of 1991 models).

Check for correct adjustment, correcting if necessary.

Cause, for example, could be an incorrectly adjusted throttle valve switch or

accelerator cable.

D 24/28 - 10

DME - Diagnosing/Troubleshooting

Printed In Germany - XXI, 1989

Advertising