NEC SIGMABLADE N8406-020 User Manual

Page 111

Advertising
background image

- 111 -

„

Cascading three FC Switch Modules (Blade Enclosure)

1.

Configuration with minimum number of cascading paths
















„

If a failure occurs on the cascading path between the FC Switch Modules, a
Fabric reconstruction occurs. Influence to I/O operations may occur not only
between the cascading FC Switch Modules but within each FC Switch Module
(each Blade Enclosure).

2.

Two paths configuration between the FC Switch Modules
















„

By making cascade connection between FC Switch Modules to two paths,
even if a failure occurs on one cascade path, no influence to I/O operation
occur because I/O operation is succeeded by redundant path and no Fabric
reconstruction occurs.

Blade Enclosure #2

Blade Enclosure #3

Blade Enclosure #1

Blade Enclosure #2

Blade Enclosure #3

Blade Enclosure #1