NEC SIGMABLADE N8406-020 User Manual

Page 121

Advertising
background image

- 121 -

3.

Change the port topologies.

„

Change of port topology in ports

Type "portcfggport x y" to change the topology of a port.

Value "x" is the number of the port whose topology is to be changed.

External ports available to N8406-019: 17 - 20

External ports available to N8406-020: 17 - 23 and 0

Value "y" shows whether fixing the port topology to be set is enabled or disabled.

0 = Disable or 1 = Enable

WH040000350:admin> portcfggport 17 1
WH040000350:admin>

„

The topology of a specific port in an FC Switch Module can be changed
individually.

„

The topologies of internal ports cannot be fixed.

„

Any port for which the setting is made enabled cannot accept the connection
of a loop device.

„

Always specify "Enable" if devices are connected with which port mode is
fabric (point-to-point). If "disable" is selected, some connected devices may
not be recognized.

„

When cascading connection is made between the FC Switch Modules, the
ports used for cascading path must be set “Enabled”.

4.

After the setting is changed completely, type "portcfgshow".

Check if the new setting resulting from the change is made effective. The setting is completed if the
information on each changed port appears as shown below.

Information on Lockd G_Port

Changing to G_Port fixing

ON

Releasing G_Port fixing

··