NEC SIGMABLADE N8406-020 User Manual

Page 44

Advertising
background image

- 44 -

(2) External Ports

The SFP ports enable the FC Switch Module to connect with fibre channel devices.

The FC Switch Module is equipped with eight SFP ports. However, available ports vary depending
on the type. See the table below for the available ports.

Available/unavailable

Port

N8406-019 N8406-020

Port 17

Port 18

Port 19

Port 20

Port 21

Port 22

Port 23

Port 0

„

An SFP module can be installed on an unavailable SFP slot. However, the
SFP module cannot connect the FC Switch Module with a fibre channel
device.

(3) Internal Ports

The internal ports allow the FC Switch Module to connect to fibre channel controllers inserted to
Mezzanine slots on the CPU blades in a Blade Enclosure (SIGMABLADE).

The FC Switch Module is equipped with 16 internal ports. However, available ports vary depending
on the type. See the table below for the available ports.

Available/unavailable

Port

N8406-019 N8406-020

Connected CPU blade

Port 1

Slot 1

Port 2

Slot 2

Port 3

Slot 3

Port 4

Slot 4

Port 5

Slot 5

Port 6

Slot 6

Port 7

Slot 7

Port 8

Slot 8

Port 9

Slot 9

Port 10

Slot 10

Port 11

Slot 11

Port 12

Slot 12

Port 13

Slot 13

Port 14

Slot 14

Port 15

Slot 15

Port 16

Slot 16

„

The slot number of the CPU blade to which a specific internal port is
connected is fixed. Changing the number is not allowed. For details, refer to
the User’s Guide of the Blade Enclosure (SIGMABLADE) you use.

Advertising
This manual is related to the following products: