Tuning method

Related Options

Description

the tuning. Adjust
the control to obtain
the maximum signal
strength. If you adjust
the setting shortly
after powering up
the radar scanner,
you should adjust it
again approximately
10 minutes after
powering up the
scanner, as the
required setting
will change after
the magnetron has
warmed up.

Adjusting analog radar gain

In the radar application:

1. Press the GAIN softkey.
2. Press the GAIN softkey repeatedly until the MAN option is

selected.

3. Using the rotary controller, adjust the gain control to the

appropriate setting (between 0 and 100%).

4. Press the OK button.

Adjusting analog radar FTC function

In the radar application:

1. Press the GAIN softkey.

2. Press the FTC softkey repeatedly until the ON option is selected.
3. Using the rotary controller, adjust the FTC function to the

appropriate setting (between 0 and 100%).

4. Press the OK button.

Adjusting analog radar rain function

In the radar application:

1. Press the GAIN softkey.
2. Press the RAIN softkey repeatedly until the ON option is

selected.

3. Using the rotary controller, adjust the Rain function to the

appropriate setting (between 0 and 100%).

4. Press the OK button.

Adjusting analog radar sea gain

In the radar application:

1. Press the GAIN softkey.
2. Press the SEA GAIN softkey repeatedly until the MAN option

is selected.

3. Using the rotary controller, adjust the Sea Gain to the appropriate

setting (between 0 and 100%).

4. Press the OK button.