Raymarine C140w User Manual

Page 127

Advertising
background image

3. Using the trackpad, highlight the required option, then press the

trackpad right to select it.

Displaying vessel vectors (CPA graphics)

1. Position the cursor over the target.
2. To display the CPA graphic for the target, press the CPA

GRAPHIC softkey until the ON option is selected.

3. To hide the CPA graphic for the target, press the CPA GRAPHIC

softkey until the OFF option is selected.

4. To display the CPA graphic automatically when you place the

cursor over any part of the MARPA symbol, select the AUTO
option.

5. Press the OK button.

MARPA options

The MARPA options are accessible by pressing the TARGET
TRACKING > MARPA & AIS OPTIONS softkeys.

Parameter

Descriptions

Options

Vector Length

The time period
specified for drawing
length of vectors.

• 0.5 min

• 1 min

• 3 min

• 6 min

• 12 min

• 30 min

• 60 min

Parameter

Descriptions

Options

Target History

Plots a target’s previous
position at specified
intervals. The four
most recent position
points are displayed.
If True target vectors
are selected, the four
most recent vessel
position points are also
displayed.

• OFF

• 0.5 min

• 1 min

• 3 min

• 6 min

Own Vessel Safe Zone

The safe zone is a ring,
centred on your boat,
within which a target is
considered dangerous
if it will enter this zone
within the Time to Safe
Zone period (see below).

• 0.1 nm

• 0.2 nm

• 0.5 nm

• 1.0 nm

• 2.0 nm

Time to Safe Zone

If a target enters your
safe zone within this time
period, it is considered
dangerous.

• 3 min

• 6 min

• 12 min

• 24 min

Safe Zone Ring

Controls whether the
safe zone ring is
displayed or hidden
on screen.

• Visible

• Hidden

Using radar

127