IP Address: Select IP Address from the IP Configuration menu to manually

configure the IP Address of the DHD Controller, as follows:

1. Press

or

to select the first, second, third or fourth byte of the address.

2. Press

or

to set the value of that byte. The range is from 0 to 255 inclusive.

3. Repeat Steps 1 and 2 for all four bytes of the address.

4. Press MENU when you have finished setting the address.

Subnet Mask: Select Subnet Mask from the IP Configuration menu to manually

configure the IP subnet mask. The procedure is similar to that for setting the IP
address.

Default Gateway: Select Default Gateway from the IP Configuration menu to

manually configure the default IP gateway. The procedure is similar to that for setting
the IP address.

Communication Test: Select Communication Test from the IP Configuration menu

to verify proper operation of the network communication link.

To start the test, select Start Test from the Communication Test menu. The DHD
Controller displays the message “Performing Communication Test.” When the test
completes, the DHD Controller displays either “Failed” (along with the error that
occurred) or “Succeeded.”

Auto Firmware Upgrade: Select Auto Firmware Upgrade from the Network menu to

enable automatic detection of a newer version of the DHD Controller firmware. If one is
found, you can configure the DHD Controller to install it automatically. These features
make it easier to keep your DHD Controller firmware up-to-date.

Auto Check For New Firmware: To have the DHD Controller automatically check

for firmware updates at periodic intervals, select Auto Check for New Firmware from
the Auto Firmware Upgrade menu and set it to On. If you prefer to do this manually,
set it to Off and use the Check For New Firmware sub-menu (described below).

Auto Perform Upgrade: If the “Auto Check For New Firmware” process

determines that a newer firmware version than the one currently installed is available,
you can have the DHD Controller automatically download and install it. To do this,
select Auto Perform Upgrade from the Auto Firmware Upgrade menu and set it to
On. The upgrade will occur the next time the DHD Controller is “power-cycled”
(powered off, then on again).
If you prefer to do this manually, set it to Off. The DHD Controller will ask if you want
to perform the upgrade the next time it is power-cycled.

Check For New Firmware: To have the DHD Controller check for new firmware on

demand (and perform an upgrade if it finds a new version), select Check For New
Firmware from the Auto Firmware Upgrade menu. If the DHD Controller finds a new
firmware version, select Yes to perform the upgrade or No to return to the previous