Omega Speaker Systems High Speed Load Cell Interface Card LCIC-WIM-BEN User Manual

Page 22

Advertising
background image

21

* The rate of updating the analog output is depends on the

Update Frequency parameter. For example, when Update
Frequency
is 4, the analog output is updated 4 times a second.

3.3.1.1 Tools / Analog Output

The ‘Settings’ utility gives access to the analog output mechanism:

Click ‘Tools’ / ‘Analog Output’.

For ‘manual’ mode uncheck the ‘Activate Auto Mode’ box.

For ‘auto’ mode check the ‘Activate Auto Mode’ box.

Manual Mode

On the top of the display, specify a desired voltage in the ‘Manual Mode’

square and click ‘Send’.

Auto Mode

Specify the following parameters:

1. Voltage Max.

2. Weight Max.

3. Weight Min.

4. Update Frequency

The Auto Mode works like this:
* When the current weight = Weight Min. or less, the analog

output is set to 0.
* When the current weight = Weight Max. or more, the analog
output is set to Voltage Max.
* When the current weight is between Weight Min. and Weight
Max.
, the analog output is set between 0 and Voltage Max., in

the same ratio.

Advertising