c. Read the RS485 address of the active board:
n

Board’s response:
’#

x

<c/r>’, where

x

is the address of the active board.

x

=0 means that the board has been configured as a non-RS485 device.

Other value (between 1 & 64) specifies the RS485 address of the active
board.

Notes

1. After sending the ‘n’ command, wait 1 second to give

chance to all 64 potential addresses to respond.

2. If no board is active, there will be no response.

3. In case of malfunction, more than one ‘#

x

<c/r>’ will be responded,

in sequence. This is theoretically impossible but should be checked
in order to be on the safe side. In this case re-activate the required
address by the ‘activate address’ command (paragraph a).

d. Set the specified RS485 address:
N

x

<c/r>

This command sets the board’s RS485 address.

x

is between

0 and 64. (

x

=0 sets the board as a non-RS485 device; this will facilitate

your coding, as no ‘:

x

<c/r>’ command will be needed.) Note: When the

RS485 address is not 0, its value is shown for a while on the LED display
upon board reset.
Board’s response: ‘OK<c/r>’.
Normally a user application will never use this command, as the address
setting is carried out using the LCIC-WIM-SETTINGS utility.