E.6 Commands

Enter & Exit Fill Mode

F

Enter Fill Mode (from General Mode)

x

Exit Fill Mode (to General Mode) (small ‘x’)

Inside the Fill Mode

g

Start filling (‘g’ stands for ‘go’) (like input #2 does).

t

Terminate an error status (like input #3 does).

e

Emergency stop (like input #4 does).

r

Get filling(s) report
Response Example:

# 1 A= 40.99 Tr= 6.65 Cv= 0.00 Ft= 7527 ms St= 2554 ms Cc= 0

Legend: Filling #1, Actual (=final) weight=40.99,
Tare=6.65, Correction Value=0.00,
Fast time=7527 ms, Slow time=2554 ms,
Completion Code=0 (0 is normal, otherwise it’s an error code).
Notes:
1. The actual (final) weight (40.99 in the example) is:

* net weight if Auto Tare is selected
* gross weight if Auto Tare is not selected.

2. The reports are accumulated in a FIFO whose size is 30
fillings. That is, only up to last 30 reports are available.
Note: The FIFO size (30) is subject to change in the various
versions.
3. Please refer also to section 3.3.2.1.4.

F

Get fillings summary:

Number of normal fillings.

Number of each error type cases for each error type

that occurred at least once.