5.4.5 SETADDR

Syntax
<address>SETADDR:<new_address><CR>

Description
Changes the communications address to a new value.

Data Parameters Sent
new_address is the new address for the monitor; Range for new_address is 1-9.

Response
<address>:<success_flag>#<checksum><CR>

Example
Command:

1SETADDR:2<CR> - Change address from 1 to 2


Response:

1:OK#261<CR>

- Change Address Successful

1:FAIL#391<CR>

- Change Address Failed


Notes
Note that monitor response is from previous address, but any further commands must be
at new address. In the example above, after sending back the OK response, the monitor
will no longer respond to commands with address 1.

P/N 03662D Teledyne API Model 460H O3 Monitor Operator Manual - Page 27