Installing the equipment, Fixing, Ventilation – TANDBERG TT1260 User Manual

Page 30: Openings in the covers, Care in positioning, 3 installing the equipment, 1 fixing, 2 ventilation

Advertising
background image

Installing the Equipment

Page 2-4

Instruction Manual: TT1260 Standard Definition Professional Receiver/Decoder

ST.TM.E10100.1

2.3

Installing the Equipment

2.3.1

Fixing

The TT1260 is designed for fixed use only and has been shipped with fixing

brackets suitable for a standard 19 inch rack. When installed in a rack, it

should be secured using the fixing brackets. In addition, support shelves

must be used to reduce the weight on the brackets. Ensure it is firmly and

safely located and it has an adequate flow of free-air.
A freestanding unit should be installed on a secure horizontal surface

where it is unlikely to be knocked or its connectors and leads disturbed.

2.3.2

Ventilation

Openings in the Covers

Side openings in the cabinet, as well as a front-mounted cooling fan, are

provided for ventilation. They ensure reliable operation of the product and

protect it from overheating. The openings or the fan must not be blocked or

covered.

Figure 2.1: Air flow Through the Equipment

Care in Positioning

CAUTIONS...

1. The fan contained within this unit is not fitted with a dust/insect filter. Pay attention to the

environment in which it is to be used.

2. Do not install units so that the air intake of one aligns with the outlet on another. Provide baffles and

adequate spacing.

The TT1260 should never be placed near or over a radiator or other source

of heat. It should not be placed in a built-in installation such as a rack unless

proper ventilation is provided and the instructions have been adhered to.
Allow at least 40 mm free air-space at each side of the equipment to

ensure adequate cooling. Racks containing stacked equipment may need

to be forced air-cooled to reduce the ambient temperature within the rack.

Air is drawn into the interior by
a front-mounted cooling fan.

Air is released through vents at both
sides of the unit.