Preventive Maintenance and Fault-finding

Page 6-6

Instruction Manual: TT1260 Standard Definition Professional Receiver/Decoder

ST.TM.E10100.1

Table 6.1: Fuse Information

Item

Specification

Fuse

Single pole, fitted in live conductor in power input filter at rear of unit.

Fuse type

5 mm x 20 mm anti-surge (T) HBC, IEC127 (sheet v)

Fuse rating

1.6 A, 250 Vac

To replace the ac power fuse perform the following:

WARNING…

BEFORE REPLACING THE REAR PANEL FUSE, DISCONNECT THE EQUIPMENT FROM THE

SUPPLY. FAILURE TO DO THIS MAY EXPOSE HAZARDOUS VOLTAGES. UNPLUG THE

EQUIPMENT FROM THE LOCAL SUPPLY SOCKET.

1. Ensure that power is turned off and the power cable is disconnected

from the ac power inlet.

2. Ease out the fuse carrier by placing a small, flat-bladed screwdriver in

the notches at the sides of the carrier.

CAUTION...

When replacing the power input fuse, always ensure that a fuse of the correct type and rating is fitted.

Failure to do so results in inadequate protection.

3. Replace the fuse in the carrier.
4. Insert the fuse carrier back in the ac power inlet.

Figure 6.2: Fuse Carrier

If the replacement fuse also blows, do not continue. Disconnect the

equipment and contact TANDBERG Customer Services (see Preliminary

Pages) for advice.

AC Power Inlet

Fuse Carrier

To access the fuse, ease out the notch
with a small flat-blade screwdriver.