Chx name (button), Channel settings (channel setup), 6 – internal settings and operations – Tascam HS-8 User Manual

Page 50

Advertising
background image

50

TASCAM HS-8

MONITOR button: Monitoring mix (same signal output

from the PHONES connector, which includes soloed

signals, etc.)

CHx NAME (button)

Edit the name of the channel (“x” is the channel).
Use the

Shift

and

Caps

buttons to change the available

character types.

Follow the same procedures to enter names as in “Editing

the project name” on page 35, with the exception that

there is no “Date” button. A maximum of 4 characters are

allowed in channel names.

Channel settings (CHANNEL SETUP)

Make settings for each channel.
Select the channel using the tabs at the bottom of the

screen.

Ana x buttons (“x” indicates the channel number): Set

analog input channel 1-8 as the input source.

Ana x buttons (“x” is “A” or “B”): Set analog input channel

A/B as the input source.

AES x/ADAT x button (“x” indicates the channel number):

Set AES/EBU digital input channel 1-8 or A/B or ADAT

input channel 1-8 as the input source.

DIGITAL SOURCE button: Touch this button to set digital

input as the input source and open the “

CHx-x

DIGITAL

SOURCE

” screen where you can select the

desired digital input connector.

REC button: Arm or disarm recording. When armed, the

button background becomes red. When recording,

the signals of tracks that are enabled are recorded.

Moreover, when a channel is armed for recording,

the signal from the assigned input connector is input

when the unit is stopped, recording or in recording

standby. (Default setting: disarmed—button not red)

INPUT MONITOR button: Use to turn input monitoring

ON/OFF. When ON for a channel, sound is always input

through its input connector.

Level knob: Touch the knob to adjust the level sent to the

stereo bus. When its background color turns yellow,

use the

DATA

dial to adjust it. Setting values range

from –∞ to +10 dB. (Default setting: 0 dB)

Pan pot: Touch the knob to adjust the stereo position of

the signal sent to the stereo bus. When its background

color turns yellow, use the

DATA

dial to adjust it.

Setting values range from L100 to R100 with C as the

center value. (Default setting: C)

Level meter: The input signal level is shown for a channel

when input monitoring is ON or recording is armed

and it is not being played back. The playback level is

shown during playback and for tracks that have input

monitoring OFF.

The area beneath each level meter shows the track

name (four characters or less) and indicates whether

recording and input monitoring are enabled.

Depending on whether or not recording and input

monitoring are enabled, the background color will

appear as follows.

REC Off

REC On

MON Off

Black

Red

MON On

Blue

Red/blue

If the input source is set to a digital input and there

is no signal on the corresponding digital input or

the input signal differs from the unit setting, the

channel meter display appears gray and the following

messages appear. (The channels are indicated by

x-x

”.)

Display

Description

AESx-x

NO

SIGNAL

If there is no input signal

ADAT NO SIGNAL

AESx-x

UNLOCK

If the input signal is not

synchronized with the system

ADAT

UNLOCK

AESx-x

NOT AUDIO

If the Cbit information of the

input signal is not audio

AESx-x NOT

PRO

If the Cbit information of the

input signal is not professional

AESx-x

Cbit

ERROR

If other input signal Cbit

information differs from the

actual operation mode

Channel name button: Touch this button to edit the name

of the channel.



button: Touch this button to open the next channel

setting screen.

6 – Internal Settings and Operations