Tektronix MTM400 User Manual

Page 102

Advertising
background image

Stream View

3-54

MTM400 MPEG Transport Stream Monitor User Manual

PCR Drift Rate (PCR_DR)

This Drift Rate graph shows the rate of change of PCR Frequency Offset, which is
often very small. It is calculated using PCR Frequency Offset measurements.

Figure 3-19: Stream view - PCR graph - PCR drift rate

The Maximum PCR Drift Rate can be adjusted for all PIDs as follows:

ƒ

Tests screen Î PCR Tests section Î PCR Drift Rate (PCR_DR)
parameter (right-click) Î Max PCR frequency drift rate.

For individual PIDs:

ƒ

PIDs screen Î Test: select PCR Drift Rate Î individual PID parameter
(right-click) Î Max PCR frequency drift rate.

ƒ

Right-click on the graph and set the limit for each PID.