Tektronix MTM400 User Manual

Page 97

Advertising
background image

Stream View

MTM400 MPEG Transport Stream Monitor User Manual

3-49

The PCR to be displayed can then be selected in the Select PCR PID dialog box.
PID numbers are displayed in decimal and hex form.

Common Elements

Statistical information for each graph is shown at the bottom of each graph. When
enabled, the View Limits checkbox ensures that the parameter limits are shown on
the Y-axis. When disabled, the data is allowed to expand to fill the available
screen. Limits are set using the parameter function on the Test and PID screens.

PCR Inaccuracy (PCR_AC)

The PCR Inaccuracy graph shows the difference between the actual and expected
values for each PCR on the y-axis. Expected PCR values are calculated from the
byte index of the PCR and the overall bitrate derived from the PCR.

Advertising