Press the LEVELS key to access this menu.
To achieve optimal performance of the 24 bit A/D converters in the M3000, the correct setting of these levels is important.
Please check the technical specifications of the connected device. The Input Peak meter should read approximately -6 to -3dB for
maximum performance.

As illustrated below the Input/Output levels are displayed in dB as well as in two more visually oriented "bars".

The levels for the right and left channel can be adjusted individually or simultaneously.
Use the CURSOR keys to select either the L or R channel, and the ADJUST wheel to change value.
Placing the cursor between the L and the R enables you to adjust the left/right levels simultaneously.

Note! The Digital In level is capable of gaining +6dB.

Digital Input gain

Place cursor between L and R to adjust simultaneously

Input gain

and sensitivity

(Consumer/PRO)

Output gain

and level

(Consumer/PRO)

LEVELS MENU

Ranges

Analog Inputs
Consumer range:

-16dBu to +10dBu

Professional range: -6dBv to +16dBv

Analog Outputs
Consumer range:

-10dBu to +16dBu

Professional range: -16dBv to +6dBv

Digital Input Level
Adjust the Digital Input from: -16dB to +6dB.