Pressure, Temperature, Tapping – True Manufacturing Company TD-50-18-S-LT User Manual

Page 15: Tdd-1 co2 knock-out

Advertising
background image

Dispensing pressures differ according to:
• The type of draft dispensing system
• The length of draft dispensing line
• The actual product - some require more,

some require less

• The temperature of the product
• The pressurizing agent: air pressure,

CO2 or special blended gases.

PRESSURE

• Correct temperature is a key factor to consider in storing

and dispensing draft beer. Too cool or too warm may cause

flavor loss, off taste and dispensing problems.

Helpful Hints on Controlling Temperature
• Keep a thermometer handy

• Monitor temperature of draft in your cooler

and at the tap

• Keep cooler door closed as much as possible

to avoid temperature fluctuation

• Regular maintenance of refrigeration equipment

is recommended

TEMPERATURE

Helpful Hints On Maintaining The Correct Pressure:

• Know which pressurizing agent to

use on which product and why.

• Monitor your regulators to ensure

applied pressure remains constant.

• Keep equipment in good repair.

Do not agitate the kegs unnecessarily. If excessive agitation

occurs allow kegs to settle for 1 to 2 hours before tapping.

Prior to tapping the keg, ensure that all beer faucet in the

serving location are in the off position. Completely remove

the dust cover (identification cap) from the keg.

TAPPING

This instruction is TRUE’s

recommended procedure for installing a

remote CO2 container.
REQUIRED TOOLS
• Pliers

• Power Drill

• Silicone Sealer

• Drill bit, 1/2”

STEP 1
Remove black knockout plug with a pair

of pliers.

NOTE:

Knockout plug for CO2 line can be

locate in two different areas. View

diagram to locate these two areas.

STEP 2

Use drill and bit to bore hole straight

back through wall into compressor

compartment.

STEP 3

Snake CO2 line through hole down

and around exiting behind rear castor

underneath rear grill.

STEP 4

Seal hole around CO2 line with silicone

sealer to prevent cold air leakage.

TDD-1 CO2 KNOCK-OUT

OF

F9

8
7

6 5 4

3

2

Knockout Plug
can be located at
either location.

INSTALLATION / OPERATION INSTRUCTIONS

True Food Service Equipment, Inc.

13

13

Advertising