Ownership, Required tools, Uncrating installation / operation instructions – True Manufacturing Company TD-50-18-S-LT User Manual

Page 6

Advertising
background image

............ www.truemfg.com ............

True Food Service Equipment, Inc.

INSTALLATION / OPERATION INSTRUCTIONS

4

4

To ensure that your unit works properly from the first

day, it must be installed properly. We highly recommend

a trained refrigeration mechanic and electrician install

your TRUE equipment. The cost

of a professional installation is money well spent.

Before you start to install your TRUE unit, carefully

inspect it for freight damage. If damage is discovered,

immediately file a claim with the delivery freight carrier.
TRUE is not responsible for damage incurred during shipment.

OWNERSHIP

• Adjustable Wrench
• Phillips Head Screwdriver
• Level

REQUIRED TOOLS

The following procedure is recommended for uncrating

the unit:
A. Remove the outer packaging, (cardboard and bubbles

or styrofoam corners and clear plastic). Inspect for

concealed damage. Again, immediately file a claim

with the freight carrier if there is damage.

B. Move your unit as close to the final location as

possible before removing the wooden skid.

C. Remove door bracket on swinging glass door models

(see image 1-2).

NOTE

Keys for coolers with door locks are located in warranty

packets.

UNCRATING

INSTALLATION / OPERATION INSTRUCTIONS

1

2

REMOTE UNITS (This section applies to remotes only!)
• Remote cabinets must be ordered as remote.

We do not recommend converting for a

standard self contained to remote system.

• All remote cabinets must be hard wired.
• No castors available.
• All remote cabinets come standard using 404A

refrigerant.

• All remote units come standard with expansion

valve, liquid line solenoid, heated condensate

pan, and defrost timer when applicable.

• Contact TRUE Technical Service for BTU

requirements.

• No wiring necessary between cabinet

and condensing unit.

• All remote condensing units purchased

from TRUE are 208/230 volts single phase.

If you have any questions regarding this section,

please call TRUE at 1-(800)-325-6152.