9.4.1 Output (Control) Data Format

The size of the output data structure from the network master to the Multicom interface is modular and
selectable from 4 to 40 bytes. The allocation of the maximum 40 bytes of the data structure is
comprised of 1 fixed four-byte command, 1 fixed four-byte extended command, 1 fixed four-byte speed
reference, 5 configurable four-byte scan data selections (selectable via drive parameters F831-F835),
and 1 eight-byte structure for asynchronous parameter accesses. Refer to Table 9 for details.

Table 9: Output (Control) data

Offset Data

Offset Data

0

Reserved

20

Parameter F833 setting high byte

1 Reserved

21

:

2

Command high byte

22

:

3

Command low byte

23

Parameter F833 setting low byte

4

Reserved

24

Parameter F834 setting high byte

5 Reserved

25

:

6

Extended command high byte

26

:

7

Extended command low byte

27

Parameter F834 setting low byte

8

Speed reference high byte

28

Parameter F835 setting high byte

9 :

29 :

10 :

30 :

11

Speed reference low byte

31

Parameter F835 setting low byte

12

Parameter F831 setting high byte

32

Action bits / Reserved

13 :

33

Reserved

14

:

34

Parameter number high byte

15

Parameter F831 setting low byte

35

Parameter number low byte

16

Parameter F832 setting high byte

36

Reserved

17 :

37

Reserved

18

:

38

Parameter data to write high byte

19

Parameter F832 setting low byte

39

Parameter data to write low byte


Locations marked “Reserved” in the above table are reserved for future use. Presently, all “Reserved”
output data locations are ignored by the drive. Future releases of the drive firmware, however, may use
these locations for data transfer.

Throughout the remainder of this section, references may be made to internal ASD parameter numbers
and data definitions. For more information regarding the specific accessible ASD parameters, please
refer to the appropriate ASD Serial Communication Interface Manual (obtainable from Toshiba).

Advertising