Toshiba G7 User Manual

Page 34

Advertising
background image

G7 ASD Multi-Protocol Communication Option and PG Feedback Option Manual

27

Drive Status Scan Data (Offsets 12 ∼∼∼∼ 31)
Table 15 provides a list of the available status scan data selections (selectable via drive parameters
F841-F846). The “Parameter” column indicates the drive’s internal parameter to which the
corresponding selection is mapped. More detailed explanations of some of these status items follow
Table 15.

Table 15: Drive Status Scan Data

F841~F846

Setting

Description Unit

Range

Parameter

0 No

selection

-

-

0xFFFF

1

Alarm code monitor

-

-

0xFC91

2

Operating speed

0.01Hz

0 ~ 40000

0xFE58

3

Real-time speed feedback

0.01Hz

0 ~ 40000

0xFE61

4

Filtered speed feedback

0.01Hz

0 ~ 40000

0xFE62

5

Internal torque reference

0.01%

-32767 ~ 32767

0xFE56

6

Output current

0.01%

0 ~ 32767

0xFE03

7

Excitation current

0.01%

-32767 ~ 32767

0xFE21

8

Torque current

0.01%

-32767 ~ 32767

0xFE20

9

Overload value

0.01%

0 ~ 10000

0xFE59

10

Accel / Decel torque
reduction

0.01%

-32767 ~ 32767

0xFE60

11

Motor counter data

-

0 ~ 65535

0xFE33

12 Fault

code

-

-

0xFC90

13 Input

terminal

-

-

0xFE06

14

VI input

0.01%

0 ~ 10000

0xFE36

15

RR input

0.01%

0 ~ 10000

0xFE35

16

RX input

0.01%

-10000 ~ 10000

0xFE37

Note 1: Parameters F841

F846 are only validated on drive reset or power-up.

Therefore, if any of these parameters are changed, be sure to reset the drive to validate
the changes.