11.5.5.2.2 Poll Connection Object Instance Attributes

Attribute

ID

Access

Rules

Name Data

Type

Description

Default

Value

1

Get

state

USINT

State of the object

--

2 Get

instance_type

USINT

Indicates connection

type

1

3 Get

transportClass_

trigger

USINT Connection

behavior 0x82

4 Get

produced_

connection_id

UINT

Placed in CAN ID field

when transmitting

0x03C0 +

MAC ID

5 Get

consumed_

connection_id

UINT

CAN ID field value

denoting received

messages

0x0405 +

(MAC ID

<< 3)

6 Get

initial_comm

_characteristics

USINT

Defines producing /
consuming message

groups

0x01

7 Get

produced

_connection

_size

UINT

Max number of bytes

transmitted across this

connection

8

8 Get

consumed

_connection

_size

UINT

Max number of bytes

received across this

connection

8

9

Get / Set

expected_

packet_rate

UINT

Defines timing

associated with this

connection

0

12

Get / Set

watchdog_

timeout_action

USINT

Inactivity/watchdog

timeout action

0

13 Get

produced_

connection_

path_length

UINT

Number of bytes in

produced_connection

_path attribute

6

14 Get

produced_

connection_

path

Array of

USINT

Specifies Application

Object(s) whose data is

to be produced by this

connection

20 04 24
96 30 03

15 Get

consumed_

connection_

path_length

UINT

Number of bytes in

consumed_

connection_path

attribute

6

16 Get

consumed_

connection_

path

Array of

USINT

Specifies Application

Object(s) whose data is

to be consumed by this

connection

20 04 24
64 30 03

17 Get

production_
inhibit_time

UINT

Defines minimum time

between new data

production

0

Advertising