Transport stream packet lengths, Asi output mode, Setting up the alarms (menu 6) – TANDBERG High Definition Professional Recevier/Decoder TT1280 User Manual

Page 53: Transport stream packet lengths -17, Asi output mode -17, Setting up the alarms (menu 6) -17, Table 3.24: setting up the alarms -17, 10 setting up the alarms (menu 6), 4 transport stream packet lengths, 5 asi output mode

Advertising
background image

Operating the Equipment Locally

Reference Guide: TT128x High Definition Professional Receiver/Decoder

Page 3-17

ST.RE.E10141.5

3.9.4

Transport Stream Packet Lengths

The input transport stream packet lengths may be 188/204/208 bytes.

With the transport stream output set to POST INPUT or POST TS

DESCRAMBLE, the output packet length is the same as the input. With the

transport stream output set to POST ES DESCRAMBLE, the output is

always 188 bytes.

3.9.5

ASI Output Mode

Spread mode in = > spread mode out (except when the TSO is set to

POST ES DESCRAMBLE in step 2 in Table 3.21. Then the output is

always bursted).

Burst mode in = > burst mode out.

3.10 Setting Up the Alarms (Menu 6)

Menu 6 allows a selection of Alarms to be edited.

Table 3.24: Setting up the Alarms

Step Action

Result

1

Go to Menu 6.

Accesses the Alarms menu.

2

Scroll to Menu 6.6 and edit the BIT ERROR
RATE range (9.9 E-1 to 1.0 E-8) and status
(NO ALARM, SET ALARM ONLY, SET
ALARM AND RELAY 1, SET ALARM AND
RELAY 2, SET ALARM AND RELAY 3, SET
ALARM AND RELAY 4, SET RELAY 1 ONLY,
SET RELAY 2 ONLY, SET RELAY 3 ONLY,
SET RELAY 4 ONLY). Press Save.

Edits the BER alarms menu.

3

Scroll to Menu 6.1 and edit the TRANSPORT
STREAM menu (NO ALARM, SET ALARM
ONLY, SET ALARM AND RELAY 1 – 4, SET
RELAY 1 – 6 ONLY). Press Save.

Edits the Transport Stream alarms menu.

4

Scroll to Menu 6.2 and edit the VIDEO menu
(NO ALARM, SET ALARM ONLY, SET
ALARM AND RELAY 1 – 4, SET RELAY 1 –
4 ONLY). Press Save.

Edits the Video alarms menu.

5

Scroll to Menu 6.3 and edit the
AUDIO 1 menu (NO ALARM, SET ALARM
ONLY, SET ALARM AND RELAY 1 – 4, SET
RELAY 1 – 4 ONLY). Press Save.

Edits the Audio 1 alarms menu.

6

Scroll to Menu 6.4 and edit the
AUDIO 2 menu (NO ALARM, SET ALARM
ONLY, SET ALARM AND RELAY 1 – 4, SET
RELAY 1 – 4 ONLY). Press Save.

Edits the Audio 2 alarms menu.

7

Scroll to Menu 6.5 and edit the
MER menu (NO ALARM, SET ALARM ONLY,
SET ALARM AND RELAY 1 – 4, SET RELAY
1 – 4 ONLY). Press Save.

Edits the MER Error Rate (00.0 to 69.9) and status menu.

8

Scroll to Menu 6.7 and edit the
TEMPERATURE menu (NO ALARM, SET
ALARM ONLY, SET ALARM AND RELAY 1 –
4, SET RELAY 1 – 4 ONLY). Press Save.

Edits the Temperature menu.

Advertising
This manual is related to the following products: