Operating the Equipment Remotely

Page 4-4

Reference Guide: TT128x High Definition Professional Receiver/Decoder

ST.RE.E10141.5

Table 4.2: Configuring the Serial Remote Port and Activating Remote Protocol

Step Action

Result

1.

Go to menu 7.1.

Displays ‘OPERATING MODE’.

2. Press

Edit.

Displays ‘FRONT PANEL’.

3.

Press the down pushbutton and select
‘SERIAL REMOTE’.

The settings should be set to match the external control host.

4. Press

Save.

The unit is ready for Remote Control.

Once the communication parameters are entered correctly, set the system

into remote mode for the external computer to gain control of the unit:

Step Action

Result

1.

Go to menu 7.1.2.

Displays ‘SERIAL REMOTE PROTOCOL’.

2. Press

Edit.

Toggle between RS-232 Alteia or RS-485 Alteia.

3.

Chose between RS-232 Alteia or RS-485
Alteia.

The settings should be set to match the external control host.

4. Press

Save.

The unit is ready for Remote Control.

4.1.5

Configuring the Unit For Remote Control Over-air

Overview

For the unit to be controlled via over-air control (OAC), the control mode

of the IRD needs to be set to Director NCP.

Table 4.3: Activating Director NCP Remote Control

Step Action

Result

1.

Go to menu 7.1.

Displays ‘OPERATING MODE’.

2. Press

Edit.

Displays ‘FRONT PANEL’.

3.

Press the down pushbutton and select
‘DIRECTOR NCP’.

The settings should be set to match the external control host.

4. Press

Save.

The unit is ready for OAC.

OAC Lockout

Once the unit is in OAC control mode, it is possible for the remote control

operator to issue a local lockout command to the Receiver. This will

effectively deny the local user access to configuring the unit.
However, if a situation occurs whereby the local user needs to regain

control over the unit, without a local lockout relinquish command being

sent from the OAC control PC, a four digit Personal Identification Number

(PIN) may be entered through the keypad.

CAUTION…

TANDBERG Television Customer Services Help Desk will not be able to provide you with the Local

lockout PIN, as it is uniquely created at the time of the lockout.

The user creates the PIN at lockout time. To obtain the PIN, please consult

the person responsible for the administration of the unit.