Cooling and mechanical construction

The Genesys

TM

series is cooled by internal fans. At the installation, care must be taken to allow free

airflow into the power supply via the front panel and out of the power supply via the rear panel. The
Genesys

TM

power supplies have a compact and lightweight package, which allows easy installation

and space saving in the application equipment.

1.3 ACCESSORIES

1.3.1 General
Accessories are delivered with the power supply or separately upon ordering. The list below shows
the possible accessories and ordering numbers.

1.3.2

Serial Link Cable

Serial link cable, for linking power supplies by RS485 communication is provided with the power sup-
ply.
Cable description: 0.5m length, shielded, RJ-45 type plugs, 8 contacts (P/N:GEN/RJ-45).

1.3.3

Misc. hardware

 DB25 plug (AMP, 749809-9).

 Strain relief for AC cord.

 Output terminal shield

 Output bus bar connection hardware.

1.3.4

AC cables

AC cables are not provided with the power supply.

Refer to Table 1-1 for recommended AC input cables (customer supplied). Add a non-locking plug
approved by the national safety standards of the county of usage.

AC Input Range

AC Input Cable

190-240V~, Three Phase

4 x 12AWG (3 wire plus safety ground), stranded
copper, 300V, 60°C minimum, rated for 25A. 3m max.
length, outer diameter: 9~11mm.

380-415V~, Three Phase

4 x 14AWG (3 wire plus safety ground), stranded
copper, 600V, 60°C minimum, rated for 15A. 3m max.
length, outer diameter: 9~11mm.

Table 1-1: Recommended AC input cable

CAUTION

Observe all torque guidelines within this manual. Over-torquing may damage
Unit or accessories. Such damage is not covered under manufacturers warranty.