TDK 2U GENESYS 5KW User Manual

Page 42

Advertising
background image

83-515-000 Rev. B

34

J1

contact

Signal

name

Function

Reference

J1-1

ENA_IN

Enable/Disable the power supply output by dry-contact
(short/open) with ENA_OUT.

Sec. 5.8

J1-2
J1-3

IF_COM

Isolated Interface Common. Return for the SO control,
PS_OK signal and for the optional IEEE interface.

Sec.5.7, 5.10

J1-47

N/C

No Connection

J1-8

LOCAL/
REMOTE

Input for selecting between Local or Remote analog pro-
gramming of Output Voltage and Output Current.

Sec. 6.2

J1-9

VPGM

Input for remote analog voltage/resistance programming
of the Output Voltage.

Sec. 6.16.4

J1-10

IPGM

Input for remote analog voltage/resistance programming
of the Output Current.

Sec. 6.16.4

J1-11

VMON

Output for monitoring the power supply Output Voltage.

Sec. 6.6

J1-12

COM

Control

Common.

Return

for

VMON,

IMON,

CV/CC,

LOC/REM.
Connected internally to the negative sense potential (-S).

J1-13

CV/CC

Output for Constant-Voltage/Constant-Current mode
indication.

Sec. 5.9

J1-14

ENA_OUT

Enable/Disable the power supply output by dry-contact
(short/open) with ENA_IN.

Sec. 5.8

J1-15

SO

Input for Shut-Off control of the power supply output.

Sec. 5.7

J1-16

PS_OK

Output for indication of the power supply status.

Sec. 5.10

J1-1720

N/C

No Connection.

J1-21

LOC/REM
SIGNAL

Output for indicating if the unit is in Local or Remote
analog programming mode.

Sec. 6.3

J1-22

VPGM_RTN

Return for VPGM input. Connected internally to the “-S”.

Sec. 6.1, 6.4,

6.5

J1-23

IPGM_RTN

Return for IPGM input. Connected internally to the “-S”.

Sec. 6.1, 6.4,

6.5

J1-24

IMON

Output for monitoring the power supply Output Current.

Sec. 6.6

J1-25

P

Output for current balance in parallel operation.

Sec. 5.15