TDK 2U GENESYS 5KW User Manual

Page 40

Advertising
background image

83-515-000 Rev. B

32

4.4.1

SW1 position function

Refer to Table 4-3 for description of SW1 position functions. The factory default setting is Down
for all positions.

Table 4-3: SW1 Positions Functions

Position

Function

DOWN (Factory default)

UP

SW1-1

Output Voltage

Remote Analog Programming

Output Voltage

Programmed by

Front Panel

Output Voltage

Programmed by remote analog

External Voltage or External Resistor

SW1-2

Output Current

Remote Analog programming

Output Current

Programmed by

Front Panel

Output Current

programmed by remote analog

External Voltage or External Resistor

SW1-3

Programming Range Select

(Remote voltage/resistive)

0-5V/(0-5Kohm)

0-10V/(0-10Kohm)

SW1-4

Output Voltage and

Current Monitoring Range

0-5V

0-10V

SW1-5

Shut-Off Logic select

On: High (2-15V) or Open
Off: Low (0-0.6V) or Short

On: High (0-0.6V) or Short

Off: Low (2-15V) or Open

SW1-6

RS232/485 select

RS232 interface

RS485 interface

SW1-7

Output Voltage

Resistive Programming

Output Voltage

programmed by

Front Panel

Output Voltage

programmed by

External resistor

SW1-8

Output Current

Resistive Programming

Output Current Limit

Programmed by

Front Panel

Output Current Limit

Programmed by

External Resistor

SW1-9

Enable/Disable control

Rear panel

Enable/Disable control is

not Active

Rear panel

Enable/Disable control

is Active

4.4.2

Resetting the SW1 switch

Before making any changes to the SW1 switch setting, disable the power supply output by press-
ing the front panel OUT button. Ensure that the Output Voltage falls to zero and the OUT LED is
off. Then use any small flat-bladed screwdriver to change the SW1 switch setting.

Advertising