7.11.3 Service Request: Enable and Event Registers
The conditional Registers are continuously monitored. When a change is detected in a register bit
which is enabled, the power supply will generate an SRQ message.
The SRQ message is: “Inn” terminated by CR, where the nn is the power supply address. The SRQ
will be generated either in Local or Remote mode.

Refer to Tables 7-11 to 7-14 for details of the Enable and Event registers.

1. Fault Enable Register
The Fault Enable Register is set to the enable faults SRQs.
Table 7-10: Fault Enable Register

BIT

Enable

bit name

Fault symbol

Bit Set condition

Bit reset condition

0 (LSB)

Spare bit

SPARE

1

AC Fail

AC

2

Over Temperature

OTP

3

Foldback

FOLD

4

Over Voltage

OVP

5

Shut Off

SO

6

Output Off

OFF

7(MSB)

Enable

ENA

User command:
“FENA nn” where
nn is hexadecimal

User command: “FENA nn”
where nn is hexadecimal (if
nn=”00”, no fault SRQs will
be generated).

2. Fault Event Register
The Fault Event will set a bit if a condition occurs and it is Enabled. The register is cleared when
FEVE?, CLS or RST commands are received.

Table 7-12: Fault Event Register

BIT

Enable

bit name

Fault symbol

Bit Set condition

Bit reset condition

0 (LSB)

Spare bit

SPARE

1

AC Fail

AC

2

Over Temperature

OTP

3

Foldback

FOLD

4

Over Voltage

OVP

5

Shut Off

SO

6

Output Off

OFF

7(MSB)

Enable

ENA

Fault condition
occurs and it is
enabled.
The fault can set a
bit, but when the
fault clears the bit
remains set.

Entire Event Register is
cleared when user sends
“FEVE?” command to read
the register.
“CLS” and power-up also
clear the Fault Event Regis-
ter. (The Fault Event Regis-
ter is not cleared by RST)