TDK 2U GENESYS 5KW User Manual

Page 31

Advertising
background image

83-515-000 Rev. B

23

1. Wires: AWG18 to AWG10.
2. Tightening torque: 4.4-5.3 Lb-inch. (0.5-0.6Nm).

Follow the instructions below for connection of the load wires to the power supply:

1. Strip approx. 10mm at the end of each of the wires.
2. Loosen the connector terminal screws.
3. Insert the stripped wires into the terminal and tighten the terminal screw securely (see Fig.3-8)

4. Loosen the two chassis screws marked “A” halfway as shown in Fig.3-9.
5. Assemble the protective shield to the chassis and tighten the two screws to fix the shield to the

chassis (see Fig.3-9). Screws tightening torque: 4.8-5.3 Lb-inch.

(0.5 - 0.6Nm)

6. Tighten the wires to one of the shield sides using ty-wrap or equivalent. Refer to Fig.3-10.

Ensure that the wire length inside the shield is long enough to provide proper strain relief.