Chapter 3 installation – TDK 2U GENESYS 5KW User Manual

Page 21

Advertising
background image

83-515-000 Rev. B

13

NOTE

Genesys

TM

power supplies generate magnetic fields, which might affect

the operation of other instruments. If your equipment is susceptible to
magnetic fields, do not position it adjacent to the power supply.

WARNING

To avoid electric shock hazard, do not insert conductive parts
through the front panel slits.

CHAPTER 3

INSTALLATION

3.1 GENERAL

This Chapter contains instructions for initial inspection, preparation for use and repackaging for ship-
ment. Connection to PC, setting the communication port and linking Genesys

TM

power supplies are

described in Chapter 7.

3.2 PREPARATION FOR USE

In order to be operational the power supply must be connected to an appropriate AC source. The AC
source voltage should be within the power supply specification. Do not apply power before reading
Section 3.3, 3.6 and 3.7.
Table 3-1 below, describes the basic setup procedure. Follow the instructions in Table 3-1 in the se-
quence given to prepare the power supply for use.

Step no.

Item

Description

Reference

1

Inspection

Initial physical inspection of the power supply

Section 3.3

2

Installation

Installing the power supply,
Ensuring adequate ventilation.

Section 3.4
Section 3.5

3

AC source

AC source requirements
Connecting the power supply to the AC source

Section 3.6
Section 3.7

4

Test

Turn-on checkout procedure.

Section 3.8

5

Load connection

Wire size selection. Local/Remote sensing. Single
or multiple loads.

Section 3.9

6

Default setting

The power supply setting at shipment.

Section 7.2.1

Table 3-1: Basic setup procedure

3.3 INITIAL INSPECTIONS

Prior to shipment this power supply was inspected and found free of mechanical or electrical defects.
Upon unpacking of the power supply, inspect for any damage, which may have occurred in transit.
The inspection should confirm that there is no exterior damage to the power supply such as broken
knobs or connectors and that the front panel and meters face are not scratched or cracked. Keep all
packing material until the inspection has been completed. If damage is detected, file a claim with car-
rier immediately and notify the TDK-Lambda Americas Inc. sales or authorized service facility nearest
you.

WARNING

The Genesys

TM

series is intended only for installation in Restricted

Access Location (RAL). Access to Hazardous parts (rear side of
the power supply) shall be prevented after installation.

Advertising