What is cascade connection – Yamaha PJP-100H User Manual

Page 44

Advertising
background image

HIERARCHICAL CONNECTION OF MULTIPLE PJP UNITS (CASCADE CONNECTION)

40

The cascade connection classifies the PJP units to be
involved in a call into the servers and clients, connects
each client to a server and establishes the call by
interconnecting the servers. While the maximum number
of locations that can be connected in normal connection
mode (mesh mode) is 4, a larger number of locations can
be connected by means of the cascade connection.

• To use the cascade connection, all of the PJP units involved in

the call should be set to one of the cascade connection modes. A
unit set to the normal connection mode (mesh mode) cannot be
connected with a unit set to a cascade connection mode.

• During a cascade connection, the audio is always reproduced in

the monaural mode even when “Speaker Mode” (page 29) is set
to “Divide”.

The maximum number of locations by

the cascade connection

Up to 8 locations can be connected by means of the
cascade connection. To establish the connection of 8
locations, you need to connect the servers and clients as
shown in the following figure.

Hierarchical Connection of Multiple PJP Units

(Cascade Connection)

What is cascade connection ?

Notes

Div. (a)

Branch A

Cascade Client

Cascade Client

Cascade Client

Cascade Client

Cascade Server

Cascade Server

Headquarter

Div. (c)

Div. (d)

Div. (b)

Example: Connecting headquarter and branch A with a 2-
location call and additionally connecting two divisions in two
different locations to each of headquarter and branch A.

Div.

Headquarter

Div.

Branch

Div.

Div.

Div.

Branch

Cascade Client

Cascade Client

Cascade Client

Cascade Client

Cascade Client

Cascade Server

Cascade Server

Cascade Server

01EN_00_PJP-100H_UCGB.book Page 40 Wednesday, August 23, 2006 3:04 PM

Advertising