Xerox NS-2260 User Manual

Page 28

Advertising
background image

The following 100FX modules are supported by F23 and F24 slots:

Part Number

Connector

Cable

Distance

2260-FMT

Duplex ST

MMF*2 km

2260-FMC

Duplex SC

MMF

2 km

2260-FJM

MT-RJ

MMF

2 km

2260-FVM

VF-45

MMF

2 km

2260-FSA2

Duplex SC

SMF*

20 km


Note:

* MMF - Multimode Fiber cable 50/125, 62.5/125

µ

m

* SMF - Single Mode Fiber cable 8.7/125, 9/125, 10/125

µ

m


Specifications
IEEE 802.3u 100BASE-FX compliant, Fixed 100Mbps, Fixed Full duplex

Optical Specifications
Part Number

Wavelength Output Power

Input Optical Power

2260-FMT

1310nm

-19 ~ -14dBm

-31dBm min. -14dBm max.

2260-FMC

1310nm

-19 ~ -14dBm

-31dBm min. -14dBm max.

2260-FJM

1310nm

-20 ~ -14dBm

-31dBm min. -14dBm max.

2260-FVM

1310nm

-20.5 ~ -15dBm

-33dBm typ. sensitivity

2260-FSA2

1310nm

-18 ~ -7dBm

-32dBm max. sensitivity


Installation steps:
1. Turn the power to the switch off.

2. Set JP1.

3. Insert the 100FX modules and screw the modules securely.

4. Turn the power to the switch on.

Advertising