Startup, Factory default settings, The link 10's factory default settings are – Xantrex Technology LINK 10 User Manual

Page 16

Advertising
background image

16

Once you have completed ALL instructions on page 15, insert the voltage
sense wire fuse, then the meter power fuse. (BLUE wire fuse first, RED
wire fuse last!) The fuse should be in a fuse holder and should be con-

nected in a smooth motion. A "ragged" power-up may cause a meter lockup.
Both the bar graph and digital display should come on.

Factory Default Settings

The Link 10 comes on in the

(Volts) mode with the display flashing to

indicate that it has been powered up from the de-powered state (see page
26). Left untouched for 10 minutes, the Link 10 will go to "sleep," turning
off the digital display leaving only the bar graph on. (This is a power-
saving feature.) Touching either the SEL or SET buttons will return the
Link 10 to the function the Link 10 was in when it went to "sleep."

The Link 10 is designed to work "out of the box." The factory default
values are appropriate for a moderate capacity 12 V liquid lead acid bat-
tery and a typical user display and function setup. Often the only change

that must be made is setting the battery capacity. You may also have to
set the appropriate Peukert's exponent for your battery (see page 26).
Special functions and display options are described beginning on page 27.

The Link 10's Factory Default Settings Are:

1.

Automatic Scanning of V, A, amp hours, and time will be OFF.

2.

Sleep Mode is ON. Turns digital display off after 10 minutes.

3.

Charge Efficiency Factor (CEF) equals 90% and learn CEF mode is on.

4.

Charged Parameters: Voltage =13.2, Charged Current =2%. The
battery must exceed 13.2 V and the current must be less, in amps,
than 2% of declared capacity for five minutes for the Link 10 to consider
the battery full.

5.

Battery capacity set to 200 amp hours.

6.

Peukert Exponent = 1.25.