Troubleshooting, Problem suggestion – Xantrex Technology LINK 10 User Manual

Page 43

Advertising
background image

43

Troubleshooting

Problem

Suggestion

No lights or display

Check Power Connections
Reset meter (page 28)

No keyboard response

Check Lock is not invoked
Reset meter (page 28)

Time Remaining Not

Check Battery Capacity (page 21)

Accurate

Check Temperature Coefficient (page 32)
Check Peukert Exponent (page 26)

Digital Display Dim

Clean front panel photo-sensor
(Between A and Ah lights)

Current Polarity Reversed

Current Shunt leads reversed (page 13)

Intermittent Operation

Corrosion or loose wires. Loosen and
reconnect all rear panel connections.
Check voltage sense and shunt wiring
at battery location.

Accumulates Negative

Charge Parameters not met. Check

Amp-hour reading

Charged Parameter values—has 100% of
kWh been returned? Charging Current is
not passing through shunt (pages 13, 22,
23, and Function F04).

Xantrex Technology, Inc. warrants that the Link 10 will measure voltage,
amperage, and amp hours within the published specifications. The Time
Remaining and LED bar graph functions are complicated and require
appropriate user setup and are therefore beyond the control of Xantrex
and are not covered by warranty. Similarly, installation wiring and specific
applications are beyond our control and are not covered by warranty.
See page 52.

Advertising