Peukert's exponent – Xantrex Technology LINK 10 User Manual

Page 42

Advertising
background image

42

Surrette and Rolls Batteries

Model Volts Res. Min. 20-Hr. rating "n"

EHG-208

6

345

208

1.42

EIG-225

6

350

225

1.54*

EIG-262

6

395

262

1.72*

24/90

12

165

90

1.16

27/12M

12

190

112

1.23

30H/108

12

230

108

1.08

HT/4D

12

348

170

1.15

HT/8D

12

450

221

1.20

*Use Max allowed "n" of 1.50

Peukert's Exponent

log

t

2

- log

t

1

log

I

1

- log

I

2

n =

log 20

- log 7.45

log 25

- log 11.25

=

=

1.301

- 0.872

1.398

- 1.051

= 1.24

Example of using Reserve Minutes @ 25 amps

and the 20-hour rate to calculate "n".

First convert Reserve Minutes to hours, then find the discharge current at
for the 20-hour rating. Finally, use a calculator to solve the arithmetic.

Trojan T-105:

Reserve Minutes = 447 min @ 25 amps.

t

1

= 447 min = 447/60 = 7.45 hrs

I

1

= 25 amps

20-hour rating = 225 Ah

t

2

= 20 hours

I

1

= 225 amp hours/20 hours = 11.25 amps

Advertising