Lift truck installations – Xantrex Technology LINK 10 User Manual

Page 48

Advertising
background image

48

+

-

-

-

+

+

Lift Truck Installations

Installation of the Link 10 in lift trucks, which have the motive pack bonded
to the chassis and also have a 12 V accessory battery bonded to the chassis,
may use the diagram below for proper wiring of the appropriate Prescaler.
The 0–100 V Prescaler is used where system voltage does not exceed
100 V at any time, including during onboard charging. In any other instance,
a 500 V Prescaler must be used. If possible, install separate Anderson (SMH)
connector so pack can be charged in truck if batteries are not changed.
This way, battery cycles will be counted.

HV

Battery

Prescaler

Black

Red

(Tagged)

Black

Red

(Tagged)

2 3 4

5 6 7 8

1

Acces.

Battery

2 A fuse. Above 250 V

use 500 V rated fuse.

Link 10

Shunt

12 V

or

24 V

Warning: Reversing input

voltage destroys Prescaler

and voids warranty.

T

O

ANDERSON CONNECT

O

R

This line is not used if DC-DC converter is installed.

Optional

DC-DC

Converter

(-)

(-)

(+)

Advertising
This manual is related to the following products: