High Voltage Prescaler

CAUTION!

1.

Installation of the Prescaler Option involves work with poten-
tially fatal voltages. NEVER work alone—have at least one person
present who can render assistance and CPR in the event of an
accident. If you have any doubt about your qualifications to
work on a high-voltage system, DON'T DO IT!

2.

When working with any DC system, even so-called ungrounded
("floating") systems with no planned chassis connection, disconnect
the negative battery terminal first.

HV

Battery

Prescaler

Note: Black wires are common within Prescaler.

Warning: Reversing input

voltage destroys Prescaler

and voids warranty.

Shunt

Black

Red

(Tagged)

Black

2 A Fuse. Above 250 V

use 500 V rated fuse.

Prescaler Part Numbers:

0–100 V 84-6000-00
0–500 V 84-6000-05

To Link 10

To Link 10

Use a Prescaler if system voltage EVER exceeds 50 V!
Then set voltage scaling with F13 (see page 50).

Red