Specifications – Xantrex Technology LINK 10 User Manual

Page 59

Advertising
background image

59

Specifications

Voltage: For 12 V–24 V systems. Optional Prescalers extend voltage range.

Standard Model: Two Auto-ranges:

0 to 19.95 V (0.05 V resolution)

20.0 to 50.0 V (0.1 V resolution)

Optional Prescalers: 0–100 V, 0–500 V (Used with standard model)

Amperage:

Low Range: + 0–40.0 amps (0.1 amp resolution)
High Range: + 500 amps (1 amp resolution)

Amp-hours:

Low Range: +0–199.9 amp hours (0.1 amp hour resolution)
High Range: + 200–1999 amp hours (1 amp hour resolution)

Time Remaining:

Low Range: 0 to 199.9 hours (0.1 hour resolution)
High Range: 0 to 255 hours (1.0 hour resolution)

Power Requirements:

9.5–40 volts DC
Current:
50–150 mA (Depends on ambient light. Display auto dims.)

28 mA (Sleep Mode—Bar Graph Display Only)

Shunt type required: 50 mV @ 500 amp
Accuracy:

Voltage: + (0.6% of reading + 1 least count of resolution)
Amperage: + (0.8% of reading + 1 least count of resolution)
Amp hours: Ah Error ~ (Time of measurement x current error)

Physical:

Max. Outer Bezel Diameter: 2.5'' (63.5 mm)
Max. Barrel diameter: 1.95" (50 mm)
Max. Depth: (from back of bezel) 3.15'' (80 mm)
Hole Cutout Size: Use 2" or 2 1/16" hole saw (52 mm)
Water Resistance: Splashproof front panel.
Weight: 8 Ounces (227 g)