Serial port, rs-232, Optional), Output format – Xantrex Technology LINK 10 User Manual

Page 49: Pin out

Advertising
background image

49

(optional)

Serial Port, RS-232

The Link 10 may be equipped to transmit serial communications data to a
personal computer or a data logging device. When equipped with the
optional RS-232 port, the Link 10 will transmit a data message once a
second. The structure of this data is as follows:

Data Rate:

9600

Data Bits:

8

Stop Bits:

1

Parity Bits:

None

Word:

ASCII Characters, comma delimited

Output Format:

Time, kWh, amps, volts, amp hours, Peukert amp hours, Peukert amps,
time remaining, bar graph state, temperature (degrees C).

Time is elapsed seconds since last amp hour reset. Kilowatt hours are signed
+ or -, amp hours are signed + or -, amps are signed + or -, volts are
positive, time remaining is in hours or tenths of hours.
Peukert amps and Peukert amp hours are compensated for Peukert's equa-
tion. These numbers are primarily intended for our development and trouble-
shooting. Please do not attempt to interpret these numbers.
The Bar Graph state is indicated by the following integers:
1<20%, 2<40%, 3<60%, 4<80%, 5<100%, 6 = Full (Charged Params met)
If the Low Battery Output is activated, the Bar Graph state is indicated as:
A<20%, B<40%, C<60%, D<80%, E<100%, F = Full (Charged Params met)

Pin Out:

The serial connection is via the DB-9 connector on the rear deck of the
Link 10. See additional notes on page 11. The pin connections are as follows:

Pin 2Receive Data line
Pin 3Transmit Data line
Pin 5Ground. This is connected to battery pack (-).
The shell of the DB-9 is NOT grounded.