Garmin GNS 430 User Manual

Page 229

Advertising
background image

GNS 430(A) Pilot’s Guide and Reference

190-00140-00 Rev. P

12-31

SECTION 12

ADDITIONAL FEATURES

Entering an identifier:

1) Select the Data Link Page. Highlight ‘TEXTUAL

METAR’ and press the ENT Key.

2) Turn the small right knob and scroll through

the list of four letter identifiers.

3) Highlight the desired identifier and press the

ENT Key.

4) The text box displays the METAR data for the

selected identifier.

5) To request an updated graphic or textual

METAR for this airport, press the MENU key
to access the page menu and select ‘Request
METAR?’.

6) The METAR Request Page is displayed. The

request option is displayed on the Textual
METAR Page.

Displaying Wind Data

Displaying wind data on the NAV Weather
Page:

1) Select the NAV Weather Page.
2) Press the small right knob. The upper left hand

corner field flashes.

3) Turn the small right knob and select

‘WINDS’.

4) Press the small right knob. The wind icons are

displayed on the NAV Weather Page.

Displaying Temperature/Dewpoints

Temperature/Dewpoints are displayed on the NAV

Weather Page.

Displaying Temperature/Dewpoints on the
NAV Weather Page:

1) Select the NAV Weather Page.

2) Press the small right knob. The upper left hand

corner data field flashes.

3) Turn the small right knob and select ‘TEMP/

DP’.

4) Press the small right knob. The Temperature/

Dewpoints are displayed on the NAV Weather
Page.

NOTE: See a complete description of all METAR,
Wind, and Temp-Dewpoint symbols at the end
of this section.

Troubleshooting

Although it is the responsibility of the facility that

installed the GDL 49 or GDL 69/69A to correct any
hardware problems, the pilot can perform some quick
troubleshooting steps to find the possible cause of a
failure.

First, ensure that the owner/operator of the aircraft

in which the GDL 49 or GDL 69/69A is installed has
subscribed to Echo Flight or XM Satellite Radio for a
Service Plan, and verify that it has been activated. Perform
a quick check of the circuit breakers to ensure the GDL 49
or GDL 69/69A has power applied. If a failure still exists,
continue to the Data Link Status Page.

The fields on the Data Link Status Page may provide

insight to a possible failure. Information displayed at this
page should be noted and provided to the repair station.
The Connectivity Message table should also provide a
clear indication of any potential internal failures. If no
indications exist, check the circuit breakers and electrical
connections to the GDL 49 or GDL 69/69A, and ensure
the unit has power applied. Repair stations are equipped
to repair the system, should a hardware failure exist.